ISO 15848-1 Class AH: What It Means for Valves

November 25, 2026 • GreyTec Team
Industrial valve with actuator and handwheel mounted on a pipe

ISO 15848-1 class AH is the tightest tightness class for valves type-tested with helium under ISO 15848-1, the international standard for fugitive emissions from industrial valves. The standard qualifies a valve design for external leakage, mainly past the stem seal and body joints, not leakage through the closed seat. A full classification combines a tightness class, an endurance class and a temperature class, so “class AH” on its own is never the whole story. This page explains what the standard tests, what the classes mean and what a reliability engineer should check on a certificate.

What ISO 15848-1 qualifies

ISO 15848-1 is a type test. A sample valve of a given design is tested to establish how much it leaks to atmosphere over a defined number of operating cycles and at defined temperatures. The current edition is ISO 15848-1:2015, published in Europe as EN ISO 15848-1, with an amendment in 2017.

The test looks at two leak paths:

  • Stem or shaft sealing, measured as a leak rate. This is where the tightness class comes from.
  • Body seals, such as the body-bonnet joint, checked separately by sniffing with a detector.

Its companion, ISO 15848-2, covers production acceptance testing of valves as they are made. Part 1 says a design can achieve a class. Part 2 checks production valves.

Tightness classes and test fluids

The standard uses two test fluids:

  • Helium, measured very precisely, often by vacuum or accumulation methods with a mass spectrometer.
  • Methane, measured as a concentration, closer to how emissions are monitored in the field.

Tightness classes are labelled A, B and C, with A the tightest. A suffix shows the test fluid: H for helium and M for methane. So:

  • AH is the tightest class with helium.
  • BH and CH allow progressively more leakage with helium.
  • AM, BM and CM are the equivalent methane classes.

Class A is demanding. It is generally associated with bellows stem seals or equivalent sealing systems for quarter-turn valves. Helium and methane classes are measured differently and are not simply interchangeable, so the test fluid must be part of any specification. The exact limits are set in the standard itself; use the current edition when writing a specification.

Endurance and temperature classes

A tightness class only means something together with the conditions it was achieved under.

Endurance classes set how many mechanical cycles the valve completed while staying in its tightness class. For isolating valves they are labelled CO1, CO2 and CO3. For control valves they are CC1, CC2 and CC3. Higher numbers mean more cycles. The standard allows a limited number of stem seal adjustments during the test, and the number used is recorded.

Temperature classes record the test temperatures, which range from cryogenic through room temperature to elevated temperatures. A valve tested only at room temperature has not shown its tightness at 200 °C.

A complete designation therefore reads as a string that names the tightness class, endurance class, number of stem seal adjustments, temperature class, pressure rating and the standard. Ask for the complete string, not just “AH”.

Why tightness matters for chlorine and other hazardous media

For media such as chlorine, hydrogen chloride and other toxic gases, external leakage is a safety issue before it is an emissions issue. A small, steady stem leak exposes operators, corrodes bolting and actuators, and on wet chlorine creates acid at the leak point. A seat that shuts off perfectly does nothing about any of this.

That is why seat tightness and fugitive emission performance must be specified separately. Class VI shut-off, for example, describes leakage through the closed seat. ISO 15848-1 describes leakage to atmosphere.

Higher classes come at a cost in stem seal design and testing. Not every service needs class AH. The right class follows from the hazard of the medium, the number of cycles and the plant’s emission limits.

What to ask for on a valve certificate

  1. The full classification string, including endurance class, stem seal adjustments and temperature class.
  2. Test fluid: helium or methane.
  3. Edition of the standard: 2006 or 2015, with or without the 2017 amendment.
  4. The valve tested: type, size and pressure class, and the range of sizes and ratings the qualification is stated to cover.
  5. Design match: the same stem seal design, materials and lining as the valves you are buying.
  6. Test body: who carried out or witnessed the test, and the date.
  7. Production testing: whether production valves are tested to ISO 15848-2.

Where fugitive emission specifications go wrong

  • “ISO 15848-1” with no class. A requirement that names the standard but not the class, endurance and temperature can be met by almost any tested design.
  • Room temperature results used for hot service. The valve was never shown to be tight at its operating temperature.
  • Too few cycles. An on/off valve on a frequently cycled duty needs a higher endurance class than one that operates a few times a year.
  • Certificate for a different design. The certificate covers another stem seal, size range or body type.
  • Seat class confused with emission class. Class VI shut-off is specified and stem leakage is assumed to follow.

What GreyTec can supply

The lined ball valve, lined plug valve and PFA lined butterfly valve that GreyTec supplies all carry ISO 15848-1 approval. On the manufacturer’s approval list, the qualified sizes run from 1/2 to 8 inch for the ball and plug valves and from 2 to 24 inch for the butterfly valve. Each certificate gives the full classification, test fluid and size range it covers, so ask for the one that matches your valve and check it against the duty.

Valve selection for chlorine is covered in valves for chlorine service.

FAQ

Is class AH better than class BH?

AH allows less leakage than BH under the same test conditions, so it is tighter. Whether it is needed depends on the medium and the plant’s emission limits. Endurance and temperature classes matter as much as the letter.

Does an AH certificate mean every valve leaks less than the AH limit?

No. ISO 15848-1 qualifies a design by testing a sample. Production valves are covered by ISO 15848-2 production acceptance testing, if specified.

Can a methane class be compared with a helium class?

Not directly. The two fluids are measured in different ways and units. Specify the test fluid you need, or ask the supplier how the result relates to your requirement.

How does ISO 15848-1 differ from API 624?

API 624 is a US type test for fugitive emissions of rising stem valves, using methane. ISO 15848-1 covers a wider range of valve types, uses helium or methane, and has tightness, endurance and temperature classes.

To request the fugitive emission certificate for a GreyTec valve, send an enquiry to GreyTec.